Environmental Praesidium Switchgear
  • Environmental Praesidium SwitchgearEnvironmental Praesidium Switchgear
  • Environmental Praesidium SwitchgearEnvironmental Praesidium Switchgear
  • Environmental Praesidium SwitchgearEnvironmental Praesidium Switchgear
  • Environmental Praesidium SwitchgearEnvironmental Praesidium Switchgear
  • Environmental Praesidium SwitchgearEnvironmental Praesidium Switchgear
  • Environmental Praesidium SwitchgearEnvironmental Praesidium Switchgear

Environmental Praesidium Switchgear

KXHXGN-12 genus Praesidium Environmental switchgear productum ab KEXR, vis transmissionis et distributionis instrumentorum in Sinis, est 12kV gas- insulata anulus retis cum retis tutelae gasi environmentalis (sicut aer siccus, nitrogen vel gas mixtus) ut insulation medium, quod est aptum ad anulum retis potentiae, copiae terminales et parvae aperturae et claudendae stationes distributionis reticulorum.
Exemplar: KXHXGN-12
Brand:KEXR

● Praecipuum pluma de Environmentalis praesidium  switchgear 

(I) Environmental tutela commoda

◆ Liberum SFgas: praesidium invironmentalem aerem, siccum, nitrogenium vel gasi environmentalis novum praesidium (ut G, AirPlus®, etc.

◆ Emissio carbonis humilis: Praeparata cum arcula retis SF, GWP (Global Warming Potentialis) nulla appropinquat.

(2) Consilium structurale

◆ Modulare consilium: Tutela Environmentalis switchgear unitas lineae advenientis, linea exitu, metering et PT dilatentur.

◆ Conclusum compages: Tutela  aequum        Tutelam invironmentalem praesidium transformatio pervenit IP67, quae est pulverulenta, umor-probatio et condensatio, ad asperam ambitum aptus.

◆ Foedus amplitudo: spatium servat quam scrinium retis AIS anulum et magis environmentally- amica est quam traditum SF₆ GIS.

(III) intelligentes optiones

Intelligens vigilantia (ut DTU, mensurae temperaturae, missio partialis vigilantia, etc.) eligi potest ad interretialem rerum accessum et operationem remotam et sustentationem cognoscendam.

 

● Technicam Parametri tutelae Environmentalis switchgear

◆ Circum ruptor Cabinet

Item

Unitas

Data

Rated Voltage

KV

12

Rated Frequency

HZ

50

 

 

Rated insulata gradu

1Min opus frequency sustinere

Voltage

Ad tempus ad tempus groud,

KV

42

Frange

48

Accensus impetus sustinere voltage(apicem)

Ad tempus ad tempus groud,

KV

75

Frange

85

1min potentia frequency voltage auxiliorum sustinere / imperium circuit (ad terram)

KV

2

Ratum Current

A

630

Rated breve terminum sustinere current valorem virtualis

Pelagus circuitu / Earthing switch

KA

25/4s

Earthing circuitu

KA

21.7/4s

Rated apicem sustinere current

Pelagus circuitu / Earthing switch

KA

63

Earthing circuitu

KA

54.5

Ratum est brevis ambitus interrumpentis currentis et temporum

KA/Time

25/30

Ratum ambitus brevis currentis claudendi (apicem)

KA

63

Rated cable increpans confractus current

A

25

Ratum ordinem operandi ruptoris     O-0.3s-CO-180s-CO

 

 

vita mechanica

Ruptor/Disconnector

Tempus

10000/3000

IP gradum

Signati arca

 

IP67

Swichgear testa

 

IP4X

Gas pressura

Rated gas praecipiens gradu (20℃, METIOR pressura)

Mpa

0.02

Ratum gas Min fuction gradum (20℃, coniecturam pressionem)

Mpa

0

Obsignandi observantia;

Annua rate lacus

%/Anno

≤0.05


Load switch arca

Item

Unitas

Data

Rated Voltage

KV

12

Rated Frequency

HZ

50

 

 

Rated insulata gradu

1Min opus frequency sustinere

Voltage

 

KV

 

 

 

 

Accensus impetus sustinere voltage(apicem)

 

KV

 

 

 

 

1min potentia frequency voltage auxiliorum sustinere / imperium circuit (ad terram)

KV

2

Ratum Current

A

630

Rated breve terminum sustinere current valorem virtualis

Pelagus circuitu / Earthing switch

KA

25/4s

Earthing circuitu

KA

21.7/4s

Rated apicem sustinere current

Pelagus circuitu / Earthing switch

KA

63

Earthing circuitu

KA

54.5

Ratum ambitus brevis currentis claudendi (apicem)

Onus switch / Earthing switch

KA

63

Rated activae onus interpellandi current

A

630

Rated clausa-loop interpellandi current

A

630

V% Rated active onus interpellandi current

A

31.5

Rated cable increpans confractus current

A

10

Rated activae onus confractus temporibus

Tempus

100

Culpa terrae current fractionis

A/Tempus

31.5/10

The current of lines and funes incurrens hians sub conditione culpae.

A/Tempus

17.4/10

vita mechanica

Ruptor/Disconnector

A/Tempus

10000/3000

IP gradum

Signati arca

 

IP67

Swichgear testa

 

IP4X

Gas pressura

Rated gas praecipiens gradu (20℃, METIOR pressura)

Mpa

0.02

Ratum gas Min fuction gradum (20℃, coniecturam pressionem)

Mpa

0

Obsignandi observantia;

Annua rate lacus

%/Anno

≤0.05


● Exumplum vexillum Protegium environmentalum switchgear 

◆ Communia technicae GB/T 1022 signa pro alta intentione switchgear et controlgear. 

◆ GB/T39063640.5kV AC metallo switchgear et instrumentorum diciones inclusarum.

◆ GB/T1985 Princeps intentione AC remotionis transitum ac præcomprehensionem switch

◆ GB/T38043.6-40.5kV AC summus intentione onus switch

◆ GB/T1984 Circuitus ruptor summus intentione AC

◆ GB/T4208 IP codice testae tutelae gradu

◆ GB/T7354 Partialis Dimissio Mensurae

◆ GB/T311.1 Coordinatio Insulatio Pars 1: Definitio, principia et regulae

 

●  Condiciones utens tutelae Environmentalis switchgear

◆ Maximum temperatum: +45 gradus Celsius;

◆  Minimum temperatus: -25 gradus Celsius;

◆ Maximum temperatum: (medium 24-horarum) +35 gradus Celsius;

◆ Maximum mediocris humiditas relativa (24 horas 1: ≤ 95%; Altitudo: ≤ 1500m; capacitas Seismica: 8 gradus;

◆ Protectio gradus: sigillum corporis impressum IP67, testam mutandi scrinium IP4x;

◆  Aer ambiens manifesto vapore et vapore aquae combustibili corrosivo pollui non debet.

◆ Non est crebra tremor violenta locus, et asperitas designandi sub duris partibus omnibus necessitatibus occurrit.

◆  Cum sub condicionibus environmental normalibus extra GB/T3906 adhibetur, usor cum KEXR aget.

 

Installation instructions

Environmental Protection Switchgear



Hot Tags: Environmental Praesidium Switchgear
Mitte Inquisitionem
Contactus info
Nam inquiries de funem genere arca archa, princeps voltage switchgear, humilis voltage switchgear et pretium album, placere relinquere vestri email ad nos et in tactus in XXIV horas.
X
Crusulis utimur ut meliorem experientiam pasco tibi praebeamus, situm negotiationis et personalize contentus analyse. Hoc situ utendo, ad nostrum crustulorum usum consentis.Privacy Policy